The tube bisects the carina and
passes down the midline
This tube can be used for feeding
This tube deviates to the right at
the carina
A. The tube bisects the carina and passes down the midline
C. This film is inadequate as the diaphragmatic hiatus has not been
included in the film and you cannot say what is happening at this
site
Explanation
The tube bisects the carina and is midline, but because the film is inadequate,
feeding cannot be authorised
Identify all the correct statements in this film